Operating Stroke
The operating stroke is the movement of the actuator caused by the operating body that is required for the switch to operate correctly.
- The actuator must normally be in the free position(FP).(The operating body is separated from the actuator.)
- The mortion of the operating body must not stop at the operating position (OP) and the reversing position(RP).
- When the operation reverse position(suitable pushing of the actuator) is set, the motion of the operating body must be adjustable based on the specified operating travel(OT) value.
- When the switch is placed in a device, the suitable pushing point of the operating body has to be 60% to 90% in the operating position(OP) to the total travel position (TTP).
Set the switch pushing distance from 60% to 90% of the specified OT value.